MX-M700N ADJUSTMENTS 6 – 36
ADJ 11
Adjusting the image quality in
scan mode
This adjustment is needed in the following situations:
* The CCD unit has been replaced.
* U2 trouble has occurred.
* The MFP control PWB has been replaced.
* The EEPROM on the MFP control PWB has been replaced.
* The scanner control PWB has been replaced.
* The EEPROM on the scanner control PWB has been replaced.
* One or more parts of the scanner (reading) section have been
replaced.
(Scan mode image quality adjustment items)
(Scan mode image quality)
The image density settings should be normally left at defaults but
should be adjusted according to user requests, if any.
11-A
Adjust the scan mode image density for all
modes at once
1)
Set the test chart (UKOG-0162FCZZ) on the original table so
that it aligns with the front frame. Then put four or five pieces of
A3 (11" x 17") paper.
2)
Go through the modes specified in Simulation 46-21.
3)
Select the adjustment item SCANNER EXP. LEVEL using the
numeric keypad.
4)
Press the Start key.
5)
Enter the image density adjustment value.
6)
Press the P or Start key.
NOTE: Adjusting the scanned image density through this simula-
tion changes the image density settings for all scan modes
to the image density level applied by carrying out this simu-
lation.
The scan-mode image density settings for individual scan modes
adjusted through Simulations 46-22, -23, -24, -25, and -45 are
changed to the image density level applied by this simulation.
Scanned images must be visually checked to ensure the post-
adjustment image density.
11-B
Scan mode image density adjustment/
individual setup (standard mode)
11-C
Scan mode image density adjustment/
individual setup (small-character mode)
11-D
Scan mode image density adjustment/
individual setup (fine mode)
11-E
Scan mode image density adjustment/
individual setup (super fine mode)
This adjustment is intended to the image mode for each scan mode
individually. In manual mode, the image density setting for each
scanned image density adjustment level (1 to 5) can be adjusted to
a custom density level.
1)
Set the test chart (UKOG-0162FCZZ) on the original table so
that it aligns with the front frame. Then put four or five pieces of
A3 (11" x 17") paper.
Image mode
Simulation for
adjustment
All-mode
adjustment
Individual
mode
adjustment
Scan mode image
density
adjustment/
individual setup
(standard mode)
Auto
mode
Binary mode
46-21
46-22
Manual
Binary mode
Scan mode image
density
adjustment/
individual setup
(small-character
mode)
Auto
mode
Binary mode
46-23
Half tone
mode
Manual
Binary mode
Half tone
mode
Scan mode image
density
adjustment/
individual setup
(fine mode)
Auto
mode
Binary mode
46-24
Half tone
mode
Manual
Binary mode
Half tone
mode
Scan mode image
density
adjustment/
individual setup
(super fine mode)
Auto
mode
Binary mode
46-25
Half tone
mode
Manual
Binary mode
Half tone
mode
00
Press [START] key.
Press [START] key, or press
[SYSTEM SETTINGS] key.
Item
Setting
range
Default
0
SCANNER EXP.
LEVEL
Scan mode image
density adjustment
0 – 99
50
0
SIMULATION 46-21
EXP.LEVEL SETUP SCANNER(AUTO SET), PRESS START.
0.SCANNER EXP.LEVEL
50
50
SIMULATION 46-21
EXP.LEVEL SETUP SCANNER(AUTO SET), INPUT VALUE 0-99,
AND PRESS START.
0.SCANNER EXP.LEVEL
00