MX-M700N FUSING SECTION N – 8
i.
Pressure roller
j.
CL roller
k. CL roller bearing
l.
Lower CL roller DG2
1)
Remove the fusing unit. (See “(1) Fusing unit”)
2)
Alternately tighten the screws to release pressure.
* When releasing the pressure, do not apply any force to the
shaded area. (Otherwise, the paper guide on the paper entry
side may be deformed.)
3)
Remove the screws and open the fusing unit.
4)
Remove the pressure roller unit.
5)
Remove the bearings from the pressure roller.
[Caution when attaching]
When installing the pressure roller to the fusing unit, be careful
not to damage the cleaning plate.
If the cleaning plate would be deformed, copy dirt would be
resulted.
6)
Remove the CL roller unit.
7)
Remove the CL roller bearings to CL roller.
8)
Remove the lower CL roller DG2 unit.
9)
Remove the CL roller bearings to lower CL roller DG2.