MX-M700N SIMULATION 7 – 70
66-36
Purpose
Operation test/Check
Function (Purpose)
Used to check interface between MFPC
controller and MDMC. (Check of the data
line or the command line)
Section
FAX
Operation/Procedure
1)
Enter the number corresponding to the check mode with 10-
key.
2)
Press [START] key.
When check is completed normally, "OK" is displayed. Incase of an
error, "NG" is displayed.
When check is "repeat," the operation is continued until the result is
NG or [SYSTEM SETTINGS] key is pressed.
66-39
Purpose
Setting
Function (Purpose)
Used to set the destination specifications.
Section
FAX
Operation/Procedure
1)
Enter the number corresponding to the destination.
2)
Press [START] key.
66-42
Purpose
Setting
Function (Purpose)
Reloads the PIC program installed to FAX
BOX.
Section
FAX
Operation/Procedure
NOTE: Before processing, permit writing to the FAX PROGRAMA.
(Cancel the write protection)
1)
Press [1] key to carry out the writing. Press [2] key to cancel.
2)
If the operation is normally completed, "OK" is displayed.
When the error occurs, "NG" is displayed.
(Cause of the ERROR)
* State is write-protection.
* PIC is not mounted.
* Access trouble to PIC
66-43
Purpose
Adjustment/Setup
Function (Purpose)
Setting of the PIC adjustment value
Section
FAX
Operation/Procedure
NOTE: Before processing, permit writing to the FAX PROGRAMA.
(Cancel the write protection)
1)
Present setting is highlight-displayed on the side of item.
2)
Use the numeric keys to enter the adjustment value. Press the
[P] key to memorizes the input value.
3)
Press [1] to writing the adjustment value collectively to PIC that
installed to the FAX BOX.
* If the operation is normally completed, "WRITING OK" is dis-
played. When the error occurs, "NG" is displayed.
1
MFPC
←
MDMC
Date line once only
2
MFPC
→
MDMC
Date line once only
3
MFPC
←
MDMC
Data line repeat
4
MFPC
→
MDMC
Data line repeat
5
MFPC
←
MDMC
Command line once only
6
MFPC
→
MDMC
Command line once only
7
MFPC
←
MDMC
Command line repeat
8
MFPC
→
MDMC
Command line repeat
SIMULATION 66-36
MFPC-MDMC I/F CHECK. INPUT 1-8, AND PRESS START.
1. MFPC<-MDMC(DATA once)
2. MFPC->MDMC(DATA once)
3. MFPC<-MDMC(DATA repeat)
4. MFPC->MDMC(DATA repeat)
5. MFPC<-MDMC(CMD once)
6. MFPC->MDMC(CMD once)
7. MDPC<-MDMC(CMD repeat)
8. MFPC->MDMC(CMD repeat)
1
SIMULATION 66-39
FAX DESTINATION SETUP.
SELECT 1-6, AND PRESS START
0. NO DESTINATION
1. JAPAN
2. U.S.A./CANADA
3. EUROPE
4. AUSTRALIA
5. CHINA
6. ASIA&OTHERS
1
SIMULATION 66-42
PIC PROGRAM RELOAD
ARE YOU SURE?
1.YES
2.NO
1
SIMULATION 66-43
PIC ADJUSTMENT VALUE WRITING.
ENABLE WRITE PIN (for FAX PROGRAM ROM)
SELECT 0-12 AND PRESS START.
0. WRITING for PIC
1.
ci_level_judge
22
2.
ci_cycle_min
10
3.
ci_cycle_max
107
4. ci_range
5
5.
ci_count
3
6.
cidetect
8
7.
fnet_level_judge
1
8.
fnet_range
3
9.
fnet_time_out
100
10.
fnet_count
3
11.
poff_time
3
12.
mswon_level_judge
3
1