MX-M316N SIMULATION 6 – 14
8-6
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check the output of the transfer
charger output current.
Section
Process (Transfer)
Operation/Procedure
1)
Select a target item to be adjusted with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [EXECUTE] key.
The set value is saved and the electric current corresponding
to the set value is output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
Item/Display
Content
Setting
range
Default value
26cpm
31cpm
35cpm
A
TC PLAIN SPX W
Primary transfer bias reference
value
Plain
paper
Front surface
5 - 35
18
18
20
B
TC PLAIN DPX W
Back surface
5 - 35
16
16
16
C
TC PLAIN SPX N1
Front surface
5 - 35
22
22
24
D
TC PLAIN DPX N1
Back surface
5 - 35
20
20
22
E
TC PLAIN SPX N2
Front surface
5 - 35
26
26
28
F
TC PLAIN DPX N2
Back surface
5 - 35
24
24
26
G
TC HEAVY1 W
Heavy paper
5 - 35
14
14
16
H
TC HEAVY1 N1
5 - 35
18
18
20
I
TC HEAVY1 N2
5 - 35
22
22
24
J
TC OHP W
OHP
5 - 35
10
10
10
K
TC OHP N1
5 - 35
14
14
14
L
TC OHP N2
5 - 35
14
14
14
M
TC ENVELOPE W
Envelope
5 - 35
14
14
16
N
TC ENVELOPE N1
5 - 35
18
18
20
O
TC ENVELOPE N2
5 - 35
22
22
24
P
TC THIN W
Thin paper
5 - 35
14
14
16
Q
TC THIN N1
5 - 35
18
18
20
R
TC THIN N2
5 - 35
22
22
24
S
TC LABEL W
Label paper
5 - 35
14
14
16
T
TC LABEL N1
5 - 35
18
18
20
U
TC LABEL N2
5 - 35
22
22
24
V
TC TAB W
Primary transfer bias reference
value
Tab paper
5 - 35
14
14
16
W
TC TAB N1
5 - 35
18
18
20
X
TC TAB N2
5 - 35
22
22
24
Y
TC POSTCARD N2
Post card
5 - 35
22
22
24
Z
TC ADSORPTION W
0 - 100
50
50
50
AA
TC ADSORPTION N1
0 - 100
50
50
50
AB
TC ADSORPTION N2
0 - 100
50
50
50
AC
TC INTERVAL BIAS W
0 - 100
50
50
50
AD
TC INTERVAL BIAS N1
0 - 100
50
50
50
AE
TC INTERVAL BIAS N2
0 - 100
50
50
50
AF
TC FRONTEDGE
0 - 100
60
60
60
AG
TC BACKEND SPX
0 - 100
90
90
90
AH
TC BACKEND DPX
0 - 100
80
80
80
1
: ‘15/Aug.
1