![Sharp MX-M265N Скачать руководство пользователя страница 87](http://html.mh-extra.com/html/sharp/mx-m265n/mx-m265n_service-manual_365744087.webp)
MX-M316N SIMULATION 6 – 8
1-2
Purpose
Operation test/check
Function (Purpose)
Used to check the sensors in the scanner
(reading) section and the related circuits.
Section
Scanner (reading)
Operation/Procedure
The operating status of the sensor is displayed.
When "MHPS" is highlighted, the scanner unit is in the home posi-
tion.
1-5
Purpose
Operation test/check
Function (Purpose)
Used to check the operation of the scanner
(reading) unit and the control circuit.
Section
Scanner (reading)
Operation/Procedure
1)
Select the operation speed with the touch panel key.
2)
Press [EXECUTE] key.
Scanning is repeated at the speed corresponding to the scan
resolution (operation speed).
When [EXECUTE] key is pressed, the operation is terminated.
2
2-1
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the auto-
matic document feeder and the control cir-
cuit.
Section
RSPF
Operation/Procedure
1)
Select the operation mode and the speed with the touch panel
key.
2)
Press [EXECUTE] key.
The RSPF repeats paper feed, transport, and paper exit oper-
ations at the speed corresponding to the scan resolution (oper-
ation speed).
When [EXECUTE] key is pressed, the operation is terminated.
<56opm>
<31opm>
2-2
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the sen-
sors and the detectors in the automatic
document feeder section and the control
circuits.
Section
RSPF
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
The code names of the sensors and the detectors which are active
are highlighted.
CAUTION: SWD_LEN and SWD_AD are not ON/OFF display.
Item/Display
Operation mode
Default value
OC SCAN
300DPI
300DPI
(248.0mm/s)
300DPI
(2480.mm/s)
400DPI
400DPI
(186.0mm/s)
600DPI
600DPI
(124.0mm/s)
1200DPI
1200DPI
(62.0mm/s)
Item/Display
Operation mode
Default value
(SINGLE)
300DPI
300DPI
(279.0mm/s)
300DPI
(279.0mm/s)
400DPI
400DPI
(279.0mm/s)
600DPI
600DPI
(186.0 mm/s)
(DOUBLE)
300DPI
300DPI
(279.0mm/s)
300DPI
(279.0mm/s)
400DPI
400DPI
(279.0mm/s)
600DPI
600DPI
(124.0 mm/s)
Item/Display
Operation mode
Default value
(SINGLE)
300DPI
300DPI
(186.0mm/s)
300DPI
(186.0mm/s)
400DPI
400DPI
(186.0mm/s)
600DPI
600DPI
(124.0 mm/s)
(DOUBLE)
300DPI
300DPI
(186.0mm/s)
300DPI
(186.0mm/s)
400DPI
400DPI
(186.0mm/s)
600DPI
600DPI
(124.0 mm/s)
Display
Content
SSET
SPF installation detection
SOCD
RSPF open/close sensor
SCOV
RSPF cover open/close detector
SPED
SPF document empty sensor
SPPD1
SPF primary paper transport sensor
SPPD2
SPF secondary paper transport sensor
SPPD3
SPF scan front sensor
SPPD4
SPF scan rear sensor
SPLS1
SPF document length sensor 1
SPLS2
SPF document length sensor 2
STMPU
SPF stamp UN installation detection
SWD_LEN
SPF document guide plate position (Unit: 0.1mm)
SWD_AD
SPF document detection volume output AD value