MX-M316N SIMULATION 6 – 69
63
63-1
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to display the shading correction
result.
Section
Scanner
Operation/Procedure
1)
Select a target color to display with [R] [G] [B] on the touch
panel.
63-2
Purpose
Adjustment
Function (Purpose)
Used to perform shading.
Section
Operation/Procedure
1)
(When RSPF model)
Press [EXECUTE] key.
Used to perform shading.
When the operation is completed, [EXECUTE] key returns to the
normal display.
63-3
Purpose
Adjustment
Function (Purpose)
Used to perform scanner (CCD) color bal-
ance and gamma auto adjustment.
Section
Scanner
Operation/Procedure
1)
Place the SIT chart (UKOG-0280FCZZ or UKOG-0280FCZ1)
on the reference position of the left rear frame side of the doc-
ument table.
2)
Select a target color of data display with [R] [G] [B] keys, and
press [OC] key.
3)
Press [EXECUTE] key.
The scanner (CCD) color balance automatic adjustment is per-
formed.
When the operation is completed, data are displayed on the initial
screen.
63-4
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to display the SIT chart patch density.
Section
Operation/Procedure
1)
Set the SIT chart (UKOG-0280FCZZ or UKOG-0280FCZ1) to
the reference position on the left rear frame side of the docu-
ment table.
2)
Select a target color of data display with [R] [G] [B] keys, and
press [OC] key.
3)
Select a data display mode.
4)
Press [EXECUTE] key.
The patch of the SIT chart is scanned.
When the operation is completed, data are displayed on the
initial screen.
63-5
Purpose
Adjustment/Setup
Function (Purpose)
Used to perform the scanner (CCD) color
balance and gamma default setting.
Section
Operation/Procedure
1)
Press [SIDE A(OC)] key.
2)
Press [EXECUTE] key, and press [YES] key
3)
The scanner (CCD) color balance and gamma are set to the
default.
Item/Display
Content
NOTE
ANALOG GAIN
ODD
Analog gain adjustment value (odd
number)
ANALOG GAIN
EVEN
Analog gain adjustment value (even
number)
DIGITAL GAIN ODD
Digital gain adjustment value (odd
number)
DIGITAL GAIN
EVEN
Digital gain adjustment value (even
number)
SMP AVE ODD
Reference plate sampling average
value (ODD)
SMP AVE EVEN
Reference plate sampling average
value (EVEN)
TARGET VALUE
Target value
BLACK LEVEL
Black output level
ERROR CODE
Error code
(0, 1-14)
(for debug)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
RSPF WHITE
LEVEL 1ST
First scan SPF front surface white
reference level
RSPF WHITE
LEVEL 2ND
SPF front surface white reference level
of the second or later scanning
GAMMA THROUGH
SIT chart scan data
COPY GAMMA
Copy mode gamma process data of the SIT chart
scan data
SCANNER GAMMA
Image send mode gamma process data of the SIT
chart scan data
SIT CHECK
SIT chart scan data/Check result