![Sharp MX-M265N Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/sharp/mx-m265n/mx-m265n_service-manual_365744038.webp)
MX-M316N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 – 14
1
12. Fan/Filter
A. MX-M316N/M266N/M315N/M315U/M356N/
M356U
*1:Destination North America and Mexico only
B. MX-M265N/M265U
No.
Name
Code
Function and operation
1
DV cooling duct
LSUFM
Cools the inside of the unit.
2
Power supply cooling
fan 1
PSFM1
Cools the inside of the unit.
3
Ozone exhaust fan
OZFM
Cools the inside of the machine
and discharges the ozone.
4
Paper exit cooling
fan
FUFM
Cools the fusing section and
the paper exit section.
5
Ozone filter
Absorbs ozone generated in
the image process section.
6*1
Ozone filter
Take in an odor to exhaust.
1
5
2
3
4
6*
1
No.
Name
Code
Function and operation
1
DV cooling duct
LSUFM
Cools the inside of the unit.
2
Power supply cooling
fan 1
PSFM1
Cools the inside of the unit.
3
Ozone exhaust fan
OZFM
Cools the inside of the machine
and discharges the ozone.
4
Paper exit cooling
fan
FUFM
Cools the fusing section and
the paper exit section.
5
Ozone filter
Absorbs ozone generated in
the image process section.
1
5
2
3
4
1
: ‘15/Aug.