MX-M316N SIMULATION 6 – 44
*1: The left of the correction amount indicates the execution result, and the right indicates the reference value.
Mode
Page number
Item/Display
(*: Correction
value)
Content
Display
range
Default value
26/31cpm
35cpm
CPY/
PRN*
1
1/2
(PROCESS)
REF (TS_OFF)
Left
GB ***
GB/DVB default value when TS is OFF
0 - 750
575
605
Right
DVB ***
0 - 650
400
430
ALL (TS_OFF)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when TS is OFF
0 - 750
575
605
Right
DVB ***
0 - 650
400
430
REF (TS_ON_C)
Left
GB ***
Copy GB/DVB default value when TS is
ON
0 - 750
460
460
Right
DVB ***
0 - 650
320
320
ALL(TS_ON_C)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when Copy TS is ON.
0 - 750
540
540
Right
DVB ***
0 - 650
400
400
REF (TS_ON_P)
Left
GB ***
Printer GB/DVB default value when TS is
ON
0 - 750
390
390
Right
DVB ***
0 - 650
250
250
ALL (TS_ON_P)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when Printer TS is ON
0 - 750
390
390
Right
DVB ***
0 - 650
250
250
MD_VG
Left
GB ***
Drum membrane decrease correction
amount GB value
0 - 255
0
0
MD_DV_LIFE
Left
GB ***
Process developer life correction amount
GB/DVB value
-127 - +127
0
0
Right
DVB ***
-127 - +127
0
0
MD_ENV
Left
GB ***
Environment correction amount GB/DVB
value
-127 - +127
0
0
Right
DVB ***
-127 - +127
0
0
MD_DUPLEX
Left
GB ***
Duplex print correction amount GB/DVB
value
0 - 255
0
0
Right
DVB ***
0 - 255
0
0
CPY/
PRN*
1
2/2 (LD)
REF (TS_OFF)
Left
LD (CP)
Laser power default value when TS is
OFF (CP/PRT)
0 - 255
For default values refer
to "Default values for
each item".
Right
LD (PRT)
0 - 255
ALL (TS_OFF)
Left
LD (CP)
Laser power value after addition or
subtraction of the correction amount
when TS is OFF (CP/PRT)
0 - 255
Right
LD (PRT)
0 - 255
REF (TS_ON_C)
Left
LD (CP)
Laser power default value when TS is ON
(CP/PRT)
0 - 255
Right
LD (PRT)
0 - 255
ALL (TS_ON_C)
Left
LD (CP)
Laser power value after addition or
subtraction of the correction amount
when Copy TS is ON (CP/PRT)
0 - 255
Right
LD (PRT)
0 - 255
MD_LD
Left
LD (CP)
Drum membrane decrease laser power
correction amount (CP/PRT)
-127 - +127
0
0
Right
LD (PRT)
-127 - +127
0
0
MD_LD_ENV
Left
LD (CP)
Environment laser power correction
amount (CP/PRT)
-127 - +127
0
0
Right
LD (PRT)
-127 - +127
0
0
OTHER
1/2
(TN/TC/MD)
TN_TMP_AREA
***
Toner control display temperature/
humidity area
1 - 8
4
4
TN_TMP_DATA
***
Toner control display temperature AD
value
0 - 1023
0
0
TN_HUD_DATA
***
Toner control display humidity AD value
0 - 1023
0
0
TC_TMP_AREA
***
Transfer display temperature/humidity
area
1 - 8
4
4
TC_TMP_DATA
***
Transfer display temperature AD value
0 - 1023
0
0
TC_HUD_DATA
***
Transfer display humidity AD value
0 - 1023
0
0
MD_VG_AREA
***
Membrane decrease drum traveling
distance area
1 - 15
1
1
MD_DV_LIFE_AREA
***
Developer life area for process
0 - 15
1
1
MD_ENV_AREA
***
Environment correction area
1 - 8
1
1
MD_DUPLEX_COUNTER
***
Duplex counter
0 - 300
0
0
MD_LD_AREA
***
Laser power area
0 - 15
1
1
MD_LD_ENV_AREA
***
Laser power environment area
0 - 8
4
4
2/2
(CRUM/CNT)
DESTINATION
Left
xx
Machine side management CRUM
destination
-
-
-
MODEL TYPE
xx
Model type of the machine
0 - 1
0
0
CRUM DEST_K
Right
xx
Crum destination
-
-
-
1
: ‘15/Aug.
1