- 19/27 -
Shanghai Siheng Motor Co Ltd
www.sihengmotor.com
P02
Parameters
Parameters No
Name
Setting rage
factory
default
Unit
Application way
P02.00
Analog speed command gain
10
~
3000
300
r/min/V
S
P02.01
Reverse direction of analog speed
command
0
~
1
0
S
P02.02
Analog speed command zero offset
compensation
-500
~
500
0
S
P02.03
Analog speed command has no
control action area
-500
~
500
0
S
P02.04
Analog speed command filter
1
~
1000
300
Hz
S
P02.05
Analog torque command gain
1
~
300
30
%/V
T
P02.06
Reverse direction of analog torque
instruction
0
~
1
0
T
P02.07
Analog torque instruction zero offset
compensation
-500
~
500
0
T
P02.08
Maximum speed limit for torque
control
0
~
4000
2500
r/min
T
P02.09
Analog torque command filter
1
~
1000
300
Hz
T
P02.10
The lower 4-bit input terminal
enforces the ON control word
0
~
15
0
ALL
P02.11
High 4 bit input terminal force ON
control word
0
~
15
0
ALL
P02.12
Reverse control word for lower 4 bit
input terminal
0
~
15
0
ALL
P02.13
Reverse control word for high 4 bit
input terminal
0
~
15
0
ALL
P02.14
Reverse control word for output
terminal
0
~
15
0
ALL
P02.15
Input terminal to dither the time
constant
1
~
1000
16
0.1ms
ALL
P03
Parameters
Parameters No
Name
Setting rage
factory
default
Unit
Application
way
P03.00
Speed trial run
0
~
1
0
S
P03.01
JOG Run
0
~
1
0
S
P03.02
Encoder zero operation
0
~
1
0
ALL
P03.03
Open loop operation
0
~
1
0
ALL
P03.04
The initial detection point of software
overcurrent
30
~
100
90
%
ALL
P03.05
Software overcurrent detection time
10
~
10000
300
0.1ms
ALL
P03.06
SON servo actuation
0
~
1
1
ALL
P03.07
System parameters initialized
0
~
1
0
ALL