3.2
Parameter setting
In the menu of the first layer, press [MODE] key to switch to
then use Parameter setting mode, and
then use
【
▲
】
、
【
▼
】
button select different parameter groups P00~P05.
Press [SET] key to enter the second layer "parameter number" menu, and use
【
▲
】
and
【
▼
】
keys to select different parameter Numbers. Press "SET" key to display the parameter values,
the parameter value of lowest twinkle, twinkle with "◄" button can be moved, with the
【
▲
】
or
【 ▼ 】
key can modify the parameter values. Press [SET] key to save the modified value,
which will be immediately reflected into the control. After that, press
【
▲
】
and
【 ▼ 】
button to
continue to modify the parameters. After the modification, press [MODE] button to return to the
parameter selection menu. If you are not satisfied with the value being modified, do not press the
[SET] key to confirm. You can press the [MODE] button to cancel, restore the original value of
the parameter, and return to the parameter selection menu.
3-3-1
Parameter setting operation block diagram
Restore parameter default value operation
The operation steps are as follows:
1. Change the password parameter P00.00 to
385, i.e. P00.00 =385.
2. Search the motor model code corresponding to
the current motor according to appendix A, and
input the motor model code into the parameter
P00.01.
3. Modify the parameter P03.07 to 1, and press
[SET] key to restore the default value of the motor.
Then power on again, using the default
parameters of the motor.
P00.