- 28/27 -
Shanghai Siheng Motor Co Ltd
www.sihengmotor.com
P01.12
External CW torque
limits
①
Set the external torque limit value of the servo motor in CCW direction.
②
The setting value is the percentage of the rated torque, for example 1 of the rated
torque X, the value is set to 100
③
This limitation is only valid if the CCW torque limiting input terminal (FIL) ON.
④
When the limit is effective, the actual torque limit is the minimum of the maximum
allowable overload capacity of the system, internal CCW torque limit and external
CCW torque limit.
0
~
300%
P01.13
External CW torque
limits
①
Set the external torque limit value of the CW direction servo motor.
②
The setting value is the percentage of the rated torque, for example 1 of the rated
torque the value is set to -100.
③
This restriction is only valid if the CW torque limit input terminal (RIL) ON.
④
When the limit is effective, the actual torque limit is the minimum absolute value of
the maximum allowable overload capacity of the system, internal CW torque limit
and external CW torque limit
-300%
~
0
P01.14
Speed
trial
operation,
JOG
operation
torque
limit
①
Set the torque limit value in the speed trial operation and JOG operation mode.
②
It has nothing to do with the direction of rotation.
③
The setting value is the percentage of the rated torque, for example 1 of the rated
torque
X, the value is set to 100.
④
Internal and external torque limits are still valid.
0
~
300%