P01.01
JOG
Running speed
①
Set the running speed of JOG operation.
-3000
~
3000
r/min
P01.02
Acceleration and
deceleration time
constant
①
The setting value is the acceleration time of the motor from 0 to 1000 r/min
②
The acceleration and deceleration characteristics are linear
③
For speed control only, position control is invalid
④
This parameter should be set to 0 if the servo driver is used in combination with an
external position ring
1
~
10000ms
P01.03
Maximum speed
limit
①
Set the maximum speed limit of the servo motor
②
It has nothing to do with the direction of rotation.
③
If the setting value exceeds the rated speed, the actual maximum speed limit is the
rated speed
0
~
6000
r/min
P01.04
Internal speed
1
①
Set internal speed 1.
②
In the speed control mode, when SC1 is OFF and SC2 is OFF, the internal speed 1
is selected as the speed instruction.
-3000
~
3000
r/min
P01.05
Internal speed
2
①
Set internal speed 2
②
In the speed control mode, when SC1 is ON and SC2 is OFF, the internal speed 2
is selected as the speed instruction.
-3000
~
3000
r/min
P01.06
Internal speed
3
①
Set internal speed 3.
②
In the speed control mode, when SC1 is OFF and SC2 is ON, select internal speed
3 as the speed instruction.
-3000
~
3000
r/min
P01.07
Internal speed
4
①
Set internal speed 4.
②
In the speed control mode, when SC1 is ON and SC2 is ON, select internal speed
4 as the speed instruction.
-3000
~
3000
r/min
P01.08
Reach the speed
①
Set arrival speed
②
In the non-position control mode, if the motor speed exceeds the set value, SCMP
ON, otherwise SCMP OFF.
③
In position control mode, this parameter is not used
④
It has nothing to do with the direction of rotation
⑤
The comparator has hysteresis characteristics
0
~
3000
r/min
P01.10
Internal CCW
The torque limit
①
Set internal torque limit value of servo motor CCW direction.
②
The setting value is the percentage of the rated torque, for example 2 of the rated
torque X, set the value to 200.
③
This restriction is valid at all times.
④
If the set value exceeds the maximum allowable overload capacity of the system,
the actual torque is limited to the maximum allowable overload capacity of the
system.
0
~
300%
P01.11
Internal CW torque
limits
①
Set internal torque limit value of CW direction servo motor.
②
The setting value is the percentage of the rated torque, for example 2 of the rated
torque
X, the value is set to -200
③
This restriction is valid at all times.
④
If the set value exceeds the maximum allowable overload capacity of the system,
the actual torque is limited to the maximum allowable overload capacity of the
system.
-300%
~
0