33
◆ Weighing Mode 4
– 3 Steps (F21 – 04 Setting) , Relay “ON” at finish point
EX) SP1(Target) = 1000, SP2(Drib) = 200, SP3(Bulk) = 500, SP4(Finish)= 50
Start Input : SP1, SP2,SP3 will be “ON”
Current weight will reaches to 500(SP1-SP3), SP3 will be “OFF”.
Current weight will reaches to 800(SP1-SP2), SP2 will be “OFF”.
Current weight will reaches to 950(SP1-SP4), SP1 will be “OFF”.
SP4(Finish) will be “ON, after SP1 relay Off and delay during “t1”time setting.
When Out3 is “ON”, the weight value is saved.
※
T1 = Finish Relay Output delay time, T2= Finish Relay output duration time
Relay Output
Relay
Contents
Relay
Contents
OUT 1
(Target)
Input “RUN” : “ON”
Current weight = Target – SP1: ”OFF”
OUT 2
(Drib)
Input “RUN” : “ON”
Current weight = Target-SP2 ”OFF”
OUT 3
(Bulk)
Input “RUN” : “ON”
Current weight = Target-SP3 ”OFF”
OUT 4
(Finish)
After reaching target value
After “t1” time,
“ON” during “t2” time
※
The weight will be measured with absolute value, it doesn’t /-.
WEIGHT