56
6-4. Analog Output Interface (0~10V)
This output card converts weight value to Analog output signal (0~10V) and transfers to
external devices(Recorder, P.L.C), controlled by voltage output.
6-4-1. Specification
This output is adjusted as when the weight is “Zero”, output is 0V and when the weight is “Full
capacity”, output is 10V. (F51-00 setting)
According to display weight of indicator, analogue signal will be output.
The operator can determine 10V output spot by setting F51 function.
Under Calibration mode or “CELL-ERR” condition, Analogue output will not activated.
If the output is deactivated, the last output signal value will be hold until next activation
6-4-2.Output Adjustment
① This output is adjusted as when the weight is “Zero”, output is “0V” and When the weight
is “Full capacity”, output is “10V”.. (F51-00 setting)
② The Analogue value is already adjusted from factory with DIGITAL MULTI-METER
③ If you need additional adjustment, please adjust with “VR1(Zero)”, “VR2(Span) on the
Analog Output PCB.
○
4
lease adjust with VR1(ZERO), VR2(SPAN) which is in the analogue out PCB.
※ Remark
This Analog option card converts Displayed weight value (Micro-process data) to analog value
on D/A Converter(Digital to Analog converter)
This D/A Converter has Max. 1/4,000 accuracy, so this output is not suitable for high accuracy
application, like more than 1/3,000.
※ For 0~5VDC or 1~5VDC analog output, please inform when you inquiry.
※ If you want to change the analogue output, Please set the Jumper pin in the analogue out
board like a following picture.
Output Voltage
0~10V DC output
Accuracy
More than 1/1,000