28
■ Other Setting Mode
EMPTY Range setting
F80
10
You can set “EMPTY” Range.
Ex) “0” setting : When Net Zero, “Zero” status lamp is ON.
“200” setting : Under “200”, “Zero” Status lamp is ON.
TIME(H,M,S) Check / Change (every 24Hours)
F90
Check Current DATE data or you can Change to new date
DATE(Y,M,D) Check / Change
F91
Check Current TIME data or you can Change to new time
SETUP Mode Password Key Setting / Change
F95
Setting the password
Change the password
.
Deactivate Lock setting
If you set password four times of
, it is unlocked.
When setting password you cannot start “SETUP” mode without password,
do not forget your password.
Program & Hard ware Version Check
F98
Check the Program & Hard ware version
Ex) “100 1.04” means H/W : ver.1.00 & S/W : ver.1.04
1) If “1” display, input 4 numbers
2) If “2” display, input the 4 numbers
once more. (recheck the password)
If “P-W” display, input the previous saved
password .
And set the “FFFF” as New password.