34
◆ Weighing Mode 5 – Packer Mode 3
3 Steps Control Packer Mode (F21 – 05 Setting), Relay “ON” at Empty range
EX) SP1(Target) = 1000, SP2(Drib) = 200, SP3(Bulk) = 500, SP4(Finish) = 50, Empty Range=10
Start Input : SP1, SP2, SP4 will be “ON”.
Current Weight reaches to Empty range(=10) , SP4 will be “OFF”.
Current Weight reaches to 500(SP1-SP3), SP3 will be “OFF”.
Current Weight reaches to 800(SP1-SP2), SP2 will be “OFF”.
Current Weight reaches to 950(SP1-SP4), SP1 will be “OFF”.
Within the Empty Range again, SP4 will “ON” .
When Out is “OFF”, the weight value is saved.
Relay Output
Relay
Contents
Relay
Contents
OUT 1
(Target)
Input “RUN” : “ON”
Current weight =Target – SP1 :”OFF”
OUT 2
(Drib)
Input “RUN” : “ON”
Current weight =Target -SP2 : ”OFF”
OUT 3
(Bulk)
Input “RUN” : “ON”
Current weight = Target-SP3 : ”OFF”
OUT 4
(Empty)
Within “EMPTY”(F80 setting) range
“ON”
※
The weight will be measured with absolute value, it doesn’t /-.
WEIGHT