DIGITAL WEIGHING INDICATOR
SI 4000
21
Tare key Operation Range selection
F09
0
Activated within 10% of Max. Capacity
1
Activated within 20% of Max. Capacity
●
2
Activated within 50% of Max. Capacity
3
Activated within 100% of Max. Capacity
“Hold” Mode selection
F10
●
0
Peak Hold : Measure Max. weight value and hold on display.
1
Sample Hold : Hold current weight until “Hold Reset”.
2
Average Hold : Measure the average of 7 seconds and hold on display
External Input Selection
F11
Set Value
Input 1
Input 2
Input 3
Input 4
0
Zero
TARE
TARE RESET
●
1
Zero
TARE/ RESET
HOLD
HOLD RESET
2
Zero
TARE/ RESET
SUB-Print
3
Zero
HOLD
HOLD RESET
“STEADY” condition check time setting
F12
03
01
∫
20
During the set time period, estimate weighing part’s “STEADY” condition and display.
If you set small value, indicator will take “STEADY” fast, if you set large value, indicator
will take “STEADY” slow.
Display Up-date rate selection (per 1sec)
F13
0
238 times
●
1
102 times
2
64 times
3
47 times
4
34 times
5
31 times
6
26 times
7
23 times
8
20 times
9
18 times
Auto TARE RESET Time Setting
F14
00
00
∫
99
Under “TARE” setting, Automatic RESET time setting mode.
“00” setting : Auto TARE reset function not use.
“05” setting : After 0.5sce, Automatic TARE reset.