3-5-2. Key Operation
Make Weight value as Zero.
Under F08, you can set the Zero key operation range, as 2%, or 5%, or 10%, or 20%
of Max. Capacity.
※
Under “Tare” key input, Zero key will not be activate within operation range.
Make Weight value as Zero, including Tare Weight.
Under F09, you can set the Tare key operation range, as 10%, 20%, 50%, or 100% of
Max. Capacity.
※
Whenever pressing “Tare” key, you can set the Tare continuously.
TARE RESET
1. Remove the Set TARE function.
- If you press this key, TARE set value will be removed and display gross weight.
FUNCTION KEY
1. “F-TEST” Mode Entrance : Press “F” key for 5sec.
2. Under “F-function Mode”, Move to next Function or move to certain function
No.(Press function No. and press “F” key)
3. Function key (Refer “Function keys”)
Hold the Weight display when indicator detects “Peak Hold”, or “Sample Hold”.
※
You can select “Hold” function on F10.
Release set “HOLD” function.
Under “TARE” setting, you can select weight display mode.
First input, Gross Weight will be displayed, second input, Net weight will be displayed.
※
This key will be activated only under “TARE” set.
Under Print installation, you can print out the “Sub-total data” of current P/N.
Printed Data : Accumulated count and weight of current P/N.
Under Print installation, you can print out the “Grand-total data” of current P/N.
Printed Data : Accumulated count and weight of All P/N.
You can set each weighing process as a certain P/N.
And you can call certain P/N with pressing this key.
P/N save : Select P/N and Enter key input.
P/N call : P/N + Number key + Enter