DIGITAL WEIGHING INDICATOR
SI 4000
24
DATA Transference Format selection(Under F32-00, F35-00 setting, only)
F37
●
0
Format 1.
1
Format 2. (Format 1 + ID No.)
2
CAS Format
3
AND Format
Transferred Data Byte selection (Weight Data, Only)
F38
●
0
7 byte Data Transfer (Decimal point Included)
1
8 byte Data Transfer (Decimal point Included)
AUTO Print Mode Selection
F39
●
0
When Weight is steady over than Empty Range, Automatically print.
1
Over than Empty Range, Steady Lamp is “ON”, Automatically Print.
■ Print Mode Setting (These settings will be apply to Serial and Parallel print)
Printed Weight Selection – Under “HOLD function” is activated
F40
●
0
Current Weight Print – HOLD value will be print.
1
HOLDED weight will be printed – current weight will not be printed.
Weight Unit selection
F41
●
0
kg
1
g
2
t
Print Format selection (If you install on Standard Serial Port)
F42
●
0
Continuous Print :
Serial No. and Weight will be printed continuously.
1
Single Print :
Date, Time, S/N, ID No. Weighing Data will be print
Print Format selection (If you install on Optional Serial Port)
F43
●
0
Continuous Print
Serial No. and Weight will be printed continuously.
1
Single Print
Date, Time, S/N, ID No. Weighing Data will be print
SUB/GRAND Total Data Delete selection
F44
●
0
Manual Delete Mode
SUB Total Delete : “Clear” key + “P/N” key
GRAND Total Delete : “Clear” key + “S/N” key
1
Automatic Delete Mode
After SUB/GRAND Total Print, Automatically Deleted.