DIGITAL WEIGHING INDICATOR
SI 4000
12
4-3-3. Formula to plan the precise weighing system
This “SI 4000” weighing controller’s Max. input sensitivity is
0.2
㎶
/ Digit
.
And for precise weighing system, the following formula must be satisfied.
Caution
: “Input sensitivity” means Min. output voltage variation of weighing part to change 1digit. So,
please do not make large input voltage to make reliable weighing system.
Singular Load cell use
A : Load cell capacity(kg)
B : Load cell Voltage(mV)
D : Digit
E : affirmation Voltage of Load cell
N : Number of Load cell
Plural Load cells use
Example1)
Number of Load cell : 1pcs
Load cell capacity : 500kg
Load cell Voltage : 2mV/V
Digit : 0.05kg
Affirmation Voltage of Load cell : 5.0V
Max. Capacity of Weighing System : 300kg
Then, estimation result for this weighing system with formula,
5000
ⅹ
2
ⅹ
0.05
= 1 ≥ 0.2
㎶
The calculated value is larger than 0.2
㎶
,
so this system has no problem.
500
Example2)
Number of Load cell : 4pcs
Load cell capacity : 500kg
Load cell Voltage : 2mV/V
Digit : 0.10kg
Affirmation Voltage of Load cell : 5.0V
Max. Capacity of Weighing System : 1,000kg
Then, estimation result for this weighing system with formula,
5000
ⅹ
2
ⅹ
0.10
= 0.5 ≥ 0.2
㎶
The calculated value is larger than 0.2
㎶
,
so this system has no problem.
500
ⅹ
4
Cautions
!