144
Operating Instructions – MOVIGEAR® SNI-B
8
Description of power section parameters
Parameters
Energy
index 8330.0
The parameter indicates the total of active electrical energy the motor has consumed:
• Storage cycle every 15 min
• Unit: [kWh]
Power section parameters \ display values \ digital inputs
Digital inputs
DI00 – DI04
index 8334.0,
bit 0 – bit 4
The parameter shows the present state of digital inputs DI00 – DI04.
Digital input DI00 is always assigned with /controller inhibit.
Digital inputs
DI00 – DI04
index 8335.0 –
8338.0
The parameter shows the current function assignment of digital inputs DI00 – DI04.
Digital input DI00 is always assigned with /controller inhibit.
Digital inputs
DI10 – DI17
index 8348.0,
bits 0 – 7
The parameter indicates the present state of the digital input of an application option
(e.g. GIO12B). If the option is not installed, the virtual digital inputs will be displayed.
Digital inputs
DI10 – DI17
index 8340.0 –
8347.0
The parameter indicates the current function assignment of the digital input of an appli-
cation option (e.g. GIO12B). If the option is not installed, the virtual digital inputs will be
displayed.
Power section parameters \ display values \ digital outputs
Digital outputs
DO10 – DO17
index 8360.0,
bits 0 – 7
The parameter indicates the present state of the digital outputs of an application option
(e.g. GIO12B). If the option is not installed, the virtual digital outputs will be displayed.
Digital outputs
DO10 – DO17
index 8352.0 –
8359.0
The parameter indicates the current function assignment of the digital outputs of an
application option (e.g. GIO12B). If the option is not installed, the virtual digital outputs
will be displayed.