106
Operating Instructions – MOVIGEAR® SNI-B
6
Startup procedure
Startup
The operating mode determines how the unit is controlled. The following table shows
the setting options:
When using MOVIFIT
®
SNI, the operating mode must be set to "SNI-SEWOS", when
using MOVIFIT
®
FDC SNI, it must be set to "VARIABLE".
NOTICE
Damage to the DIP switches caused by using unsuitable tools.
Possible damage to property.
• To set the DIP switches, use only suitable tools, such as a slotted screwdriver with
a blade width of no more than 3 mm.
• The force used for setting the DIP switches must not exceed 5 N.
6. Secure the MOVIGEAR
®
electronics covers on the connection boxes.
7. Start up the assigned SNI controller, observing the instructions in the documentation
of the controller you use.
Mode
MOVIFIT
®
SNI
(SNI-SEWOS)
Reserved
Reserved
MOVIFIT
®
FDC
(VARIABLE)
S2/1
–
X
–
X
S2/2
–
–
X
X
X = ON
–
= OFF
00
I