Assignment of optional plug connectors
Electrical installation
5.10.4 X5503: STO
The following table shows information about this connection:
Connection cable
The following table provides an overview of the cables available for this connection:
Function
Connection for safe torque off (STO)
Connection type
M12, 5-pole, male, A-coded
Wiring diagram
2264818187
Assignment
No.
Name
Function
1
res.
Reserved
2
STO
−
STO
−
connection
3
res.
Reserved
4
STO +
STO + connection
5
res.
Reserved
2
1
5
4
3
INFORMATION
Use only shielded cables for this connection and only suitable plug connectors that
connect the shield with the unit in an HF-capable manner.
Connection cable
Confor-
mity / part
number
Cable type
Length/
Installa-
tion
type
Cable
cross-
section /
operating
voltage
M12, 5-pole,
A-coded
M12, 5-pole,
A-coded
CE:
1 812 496 8
LEONI
BETAflam
®
– 145C-flex
Variable
2 ×
0.75 mm
2
/
DC 60 V
CE / UL:
1 814 740 2
HELU-
KABEL
®
MULTI-
SPEED
®
–
500-C-PUR
UL/CSA
Variable