22
Operating Instructions – MOVIGEAR® SNI-B
3
Example nameplate and type designation of electronics
Unit structure
3.8.3
Type designation of connection unit
The following table shows the type designation of the connection unit:
3.8.4
Type designation of application options
The following table shows the type designation of application options:
Note on the ver-
sion of the applica-
tion option
M G x B – SNI / DSP
Connection unit option
DSP = Electrodynamic
deceleration function DynaStop
®
MOVIGEAR
®
installation technology
SNI
= Single Line Network Installation
MOVIGEAR
®
version
Product line
MG = MOVIGEAR
®
G IO 1 2 B
Version
Design
2
= 4 digital 2 digital outputs
3 = 4
digital
inputs
(2 inputs can be used as primary frequency input)
+ 1 digital output
+ 1 analog input
+ 1 analog output
Version
Functionality
IO = Digital inputs/outputs
Product line
G = Option for MOVIGEAR
®
/ DRC
INFORMATION
For electronics covers in die-cast design, you can only use application options
GIO12B and GIO13B. For electronics covers in sand-cast design, you can only use
application options GIO12A and GIO13A .
You can identify units with die-cast housing by means of the type designation of the
electronics cover.
Application options
Design
Part number
GIO12A application option
On request
GIO13A application option
On request
GIO12B application option
Part number 1 823 801 7
GIO13B application option
Part number 1 822 652 3