Operating Instructions – MOVIGEAR® SNI-B
139
8
Description of application option parameters
Parameters
You can activate the digital inputs using DIP switch S1/2 of the application option
(activated = DIP switch set to "ON").
Digital input DI11
index 9619.11,
bit 1
The parameter indicates the state and function of digital input DI11 of the application op-
tion.
You can activate the digital inputs using DIP switch S1/2 of the application option
(activated = DIP switch set to "ON").
Digital input DI12
index 9619.11,
bit 2
The parameter indicates the state and function of digital input DI12 on the application
option.
You can activate the digital inputs using DIP switch S1/2 of the application option
(activated = DIP switch set to "ON").
Digital input DI13
index 9619.11,
bit 3
The parameter indicates the state and function of digital input DI13 on the application
option.
You can activate the digital inputs using DIP switch S1/2 of the application option
(activated = DIP switch set to "ON").
Frequency input
LFI10
index 9619.26
LFI10 frequency input of the application option.
You can activate the frequency input using DIP switch S2/1 of the application option
(activated = DIP switch set to "ON").
The scaling is:
0 Hz
Ⳏ
0 digit
The maximum frequency is set to
Ⳏ
± 32767 digits
The maximum frequency is set using DIP switches S2/2 to S2/4.
Track A mode: 0 – 32767 digits
Tracks A/B mode: – 32767 digits – +32767 digits
You set the mode of the frequency input using DIP switch S3/1.
00
I