98
Operating Instructions – MOVIGEAR® SNI-B
5
Assignment of optional plug connectors
Electrical installation
5.10.5 STO jumper plug
The STO jumper plug can be connected to the STO plug connector X5502 of the
MOVIGEAR
®
drive unit. The STO jumper plug deactivates the safety functions of the
MOVIGEAR
®
drive unit.
The following figure shows the STO jumper plug, part number 1 174 709 9:
WARNING
Safety-related disconnection of the MOVIGEAR
®
drive unit is not possible when using
the STO jumper plug.
Severe or fatal injuries.
• You may only jumper the STO input with 24 V when the MOVIGEAR
®
drive unit
need not fulfill any safety function.
WARNING
Disablement of safety-related disconnection of other drive units due to parasitic volt-
ages when using an STO jumper.
Severe or fatal injuries.
• You may only use the STO jumper when all incoming and outgoing STO connec-
tions have been removed from the drive unit.