Configuring the PROFINET IO controller
PROFINET IO Configuration
3. Choose the required station.
The SEW station appears under unit type. The default device name is 'PNETDevice-
Name' and must be changed appropriately. Several MOVI-PLC
®
advanced
DHR41B
can be distinguished from each other by their displayed MAC address. A label with
the MAC address is attached to the DHR41B option.
4. Enter the device name in the 'Device name' input field [6] and click the [Assign name]
button [7].
The device name can have up to 255 characters. The device name is transferred to
and saved in the station.
Click on [Reset] to reset the device name of MOVI-PLC
®
advanced
DHR41B online.
This requires a restart of DHR41B.
5. Specify an IP address [2] and a subnet mask [3] as well as a router address [4], if
required.
Click the [Assign IP configuration] button [5].
6. Check whether the settings have been applied by once again clicking the [Browse]
button [1].
7. Click the [Close] button [8].
TIP
The IO controller must not yet be in a cyclic data transmission with the IO devices.