110
Manual – MOVI-PLC® advanced DHR41B for EtherNet/IP, Modbus/TCP and PROFINET IO
11
Parameterization via PROFIdrive data record 47
Operating Behavior (PROFINET IO)
Query parameter response
The following table shows the coding of the READ.request user data including the
PROFINET header.
Positive MOVILINK
®
parameter setting response
The table shows the READ.response user data with the positive response data of the
parameter setting request. The parameter value for index 8300 (firmware version of
DHR41B) is returned as an example.
Service
READ. request
Description
API
0
Fixed setting = 0
Slot_Number
0
Random (is not evaluated)
Subslot_Number
1
Fixed setting = 1
Index
47
Index of the dataset for the parameter request; constant index 47
Length
240
Maximum length of response buffer in the master
Service
READ. request
Description
API
0
Fixed setting = 0
Slot_Number
0
Random (is not evaluated)
Subslot_Number
1
Fixed setting = 1
Index
47
Index of the dataset for the parameter request; constant index 47
Length
10
Maximum length of response buffer in the master
Byte
Field
Value
Description
0
0x01
Reflected reference number from the parameter set-
ting request
1
Response ID
0x40
Positive MOVILINK
®
response
2
Axis
0x00
0 = DHR41B
3
No. of parameters
0x01
1 parameter
4
Format
0x43
Parameter format: Double word
5
No. of values
0x01
1 value
6, 7
Value High
0x311C
Higher-order part of the parameter
8, 9
Value Low
0x7289
Lower-order part of the parameter
Decoding:
0x 311C 7289 = 823947913 dec
>> firmware version 823 947 9.13