11
Parameterization via PROFIdrive data record 47
Operating Behavior (PROFINET IO)
11.3.2 Structure of the PROFINET parameter channel
Generally, the parameter setting of the devices to the PROFIdrive-Base Mode Parame-
ter Access of profile version 4.0 is implemented via data record 47. The
Request ID
entry
is used to distinguish between parameter access based on PROFIdrive profile or via
SEW-MOVILINK
®
services. The following table shows the possible codes of the individ-
ual elements. The data record structure is the same for PROFIdrive and MOVILINK
®
access.
The following MOVILINK
®
services are supported:
• 8-byte MOVILINK
®
parameter channel with all the services supported by the station
such as
– READ parameter
– WRITE parameter
– WRITE parameter volatile
– etc.
62206AXX
Field
Data type
Values
Unsigned8
0x00
Reserved
0x01 - 0xFF
Request ID
Unsigned8
0x40
SEW MOVILINK® service
0x41
SEW Data Transport
Response ID
Unsigned8
Response (+):
0x00
Reserved
0x40
SEW MOVILINK® service (+)
0x41
SEW Data Transport
Response (-):
0xC0
SEW MOVILINK® service (-)
0x41
SEW Data Transport
Unsigned8
0x00 - 0xFF
Number of axes 0 - 255
No. of parameters
Unsigned8
0x01 - 0x13
1 - 19 DWORDs (240 DP-V1 data bytes)
Attribute
Unsigned8
For SEW-MOVILINK® (Request ID = 0x40):
0x00
No service
0x10
READ Parameter
0x20
WRITE Parameter
0x40
Read Minimum
0x50
Read Maximum
0x60
Read Default
0x80
Read Attribute
0x90
Read EEPROM
0xA0 - 0xF0
reserviert
SEW Data Transport:
0x10
Wert
No. of Elements
Unsigned8
0x00
For parameters that are not indexed
0x01 - 0x75
Quantity 1 - 117
Parameter Number
Unsigned16
0x0000 - 0xFFFF
MOVILINK
®
parameter index
Subindex
Unsigned16
0x0000
Format
Unsigned8
0x43
Double word
0x44
Error
No. of Values
Unsigned8
0x00 - 0xEA
Quantity 0 - 234
Error Value
Unsigned16
MOVILINK
®
Additional Code Low
For SEW MOVILINK® 16 bit error value
READ/WRITE
PROFIdrive
Parameter Channel
DS47
SEW MOVILINK
®
Record
0
0
I