Installation Instruction
PIUMA MILLENNIUM
WARNING
Define the Master door (see Set Dip-Switch paragraph) before performing the connections. It will not be possible to determine the Master
or Slave door after completing the wiring.
WARNING
Both devices should be connected to the same power supply branch with no switches or fuses between them.
The SAFE CLOSE, KEY, START 1 and START 2 peripherals, if any, should be connected to the Master door.
The safety sensors (Safe Open) should be connected and controlled separately on both circuit cards.
The two terminals of the selector should be connected to ensure that both MILLENNIUM circuit cards communicate with each other and
that both devices function properly.
(Fig. 30)
The selector (optional) is connected to the Master card only, using the same terminal board J17 used to connect the two automatisms to
one another. Any parameters that need to be changed will be the same for both cards.
Double doors should be moved in asynchronously (see Set Dip-Switch paragraph) if there is a central jamb between them. The default set-
tings are 3 (opening) and 5 (closing), and can be modified using MILLENNIUMWARE.
The doors will only start to close when both are wide open. If one door opens completely before the other one, it will wait until the latter is
completely open.
Both doors reverse at the same time (START 1 or 2, SAFE CLOSE, anti-crush safety device, etc.).
The electric lock functions can be entered on both circuit cards in exactly the same way as with single devices by selecting Dip S7.
The Push&Go function can be activated on both devices in exactly the same way as with single devices. If it is detected that one of the
devices is trying to open a door, this will cause both doors to open.
The anti-crush safety devices and obstacle detection functions are controlled separately and independently by both cards.
If one card detects an anti-crush device whilst closing, it will stop the motion of both doors and open them completely at low speed.
If one card detects an anti-crush device whilst opening, it will stop the motion of the door involved and open it completely at low speed.
The other door, which will have opened completely in the meantime, will wait for the door involved before proceeding to close.
WARNING
The parameters that can be modified with MILLENNIUMWARE are separate on each card. If the motion parameters are modified, the same
values must be set on both cards to prevent malfunctions.
Piuma Doppio connection and use
Left Control Unit
Right Control Unit
Selector Connection
(Optional)