Installation Instruction
17
PIUMA MILLENNIUM
* NA = Normally open NC = Normally closed
The electrical signal from external peripherals can be varied through the advanced selector or PC connection: from nor-
mally closed to normally open and vice versa. See the advanced selector used manual for further details.
G. Connector for PC - unit connections
A PC connection board (optional) is required to connect the MILLENNIUM unit to a Personal Computer.
The following is possible with MILLENNIUMWARE software:
•
Advanced adjustments of some operating parameters
•
Diagnostics and advanced information on unit status
•
Microprocessor programming
PC connection board
Fig. 28
SIGNAL
TYPE * DESCRIPTION
FUNCTION
COM
Common electrical signal.
SAFE CLOSE
NC
Signal for the connection of an external
photocell or safety control device for
door closing
If the door is closing and the contact opens, the unit sends and
immediate motion inversion command. Closing will only recom-
mence after the contact closes.
The signal must be short circuited with COM if not devices
(internal or external) are connected.
AUX IN
NA
Auxiliary input signal. Auxiliary devices
can be connected to this signal. It is
normally used for inter lock functions.
When used as an auxiliary signal the function logic can be per-
sonalised according to customer requests.
When used as inter lock logic, closing this signal inhibits door
functions that will not open even with open signal presence.
AUX OUT
Auxiliary output signal, PNP transistor
type for particular door condition sig-
nals (reset, open, closed, etc).
According to the type chosen signal, the output becomes active
(12Vdc and led on) when the door is in the set condition (Reset,
open, closed, etc). See the advanced selector manual for further
details.
SAFE OPEN NA
Signal for the connection of sensors for pro-
tection during door opening.
If the door is opening and the contact closes, the unit sends an
immediate movement stop command. Opening will only continue
after this signal is deactivated.
KEY
NC
Lock signal. Closure devices can be
connected such as electronic key, key
selector, transponder, etc.
The signal can be controlled in bi or
mono-stabile mode with an activation
time equal to about 500 msec. For
mode type selection see paragraph
FIRST INPUT MODE SELECTION
.
If the signal opens the unit sends a complete door closure com-
mand (from any position) From this moment until the signal is
closed the door stays in this position and no external peripheral is
detected (including multi-logic selectors). As soon as the signal
closes the door opens permitting access.
The signal must be short circuited with COM if no devices are
connected.
START 1
NA
Opening signal. Door opening devices
can be connected.
Closing this signals causes the doors to open. This signal is only
monitored in 2 Radar logic.
START 2
NA
Opening signal. Door opening devices
can be connected.
Closing this signals causes the doors to open. This signal is moni-
tored in both 2 Radar and 1 Radar logic.