DMO Mode
In Direct Mode Operation (DMO), radios communicate directly with other
TETRA radios without using a network. The radios must all switch to DMO
and select the same talkgroup, and that talkgroup must use the same channel
(frequency). Communications to other users on the network are impossible
unless they also switch to DMO and select the same talkgroup.
Note:
This means that in DMO, communications to the dispatcher is
impossible unless they also switch to DMO and select the same talkgroup,
or if they communicate through a
DMO gateway
(see
DMO gateway
operation
on page 1).
Group calls
DMO supports group calls (see
) which are made and
received in the same way as radios operating in TMO. In DMO TETRA Alarm
Calls are either sent to the currently selected DMO talkgroup or (if
customised) may switch to TMO to make the call. If TMO is unavailable
Alarm Calls are made using DMO. See
Individual calls
Your radio can be customised to allow you to make individual calls to other
radios working in DMO which are attached to the same talkgroup. In this
case individual calls are initiated by pressing the PTT key. See
individual calls (half-duplex mode)
. (Individual calls to radios which
have selected different DMO talkgroups are prevented unless the DMO
talkgroups have the same carrier frequency.)
Your radio can also be customised to allow you to select a
channel only
talkgroup. If you select a channel only talkgroup
your radio cannot make or
receive group calls
: it can only make or receive individual calls.
Tip:
You can enable
Presence Checking
so that your radio checks
whether the receiving radio is available to receive when you attempt an
Individual call. See
.
88
SC20 series – 04/2016
Содержание SC20 series
Страница 1: ...User Guide SC20 series hand portable radio ...
Страница 8: ...viii SC20 series 04 2016 ...
Страница 40: ...Press a dedicated soft key Sepura default is normally key 0 zero Press Menu Help 32 SC20 series 04 2016 ...
Страница 153: ...2 Secure the accessory in position by rotating the screw clockwise Do not over tighten User Guide 145 ...
Страница 157: ...Sepura plc 9000 Cambridge Research Park Beach Drive Waterbeach Cambridge CB25 9TL United Kingdom sepura com ...