No.11S098-03
8
STC-GE33OX/GEC33OX
Users guide Rev. 1.03
1.2.1 Input signal
TRG IN: Input the trigger signal
High: Voltage of the
“IO VCC IN”
Low: Smaller than 0.4V
1.2.2 Output signals
Set the output signals from the power/IO connector.
The following six output signals are selectable with the software or communication.
A) FrameTriggerWait
The user can check the camera conditions, which are the camera expose and the image output
processing by the trigger signal with this FrameTriggerWait signal.
a) High status (Voltage of the
“IO VCC IN”): No processing by the trigger signal
The camera accepts the trigger signal
b) Low status (0V):
The camera is expose and the image output processing by
the trigger signal
The camera default setting is the input trigger signal is INVALID while low status for this signal.
When the exposure starts while the image output by next trigger signal, please change the camera setting
(Device code: 00H, Command: 13H) to accept the trigger signal while the image output.
The noise appears on the image when start exposure while the image output. In this case, please change
the
“H reset” for the exposure start mode (Device code: 00H, Command: 12H) to change the exposure
start point to next HD timing.
B) UserOutput
The status of this UserOutput signal can change with the
“UserOutputValue”.
C) ExposureActive
The user can check the exposure time with this ExposureActive signal.
a) High status (Voltage of the
“IO VCC IN”): The camera is exposing
b) Low status (0V):
The camera is not expose
D) TriggerAuxiliary
This TriggerAuxiliary signal is the input trigger signal.
E) TriggerInternal
This TrigerInternal signal is the input trigger signal with the trigger delay time.
F) SensorReadOut
This SensorReadOut signal is the FVAL signal, which is the image output period of the time.
G) StrobeSignal
The StrobeSignal signal is the strobe control signal.