No.11S098-03
56
STC-GE33OX/GEC33OX
Users guide Rev. 1.03
Command No.
90H:
STROBEON_I
[7..0]
91H:
STROBEON_I
[15..8]
92H:
STROBEON_I
0:
No strobe signal output
[23..16]
1 to 9:
Active time is 10 useconds
More than 10
Active time is as set time
93H:
STROBEON_F
Initial data: STROBEDELAY_F[23..0]
=
0, data range: 0 to 99
[7..0]
F0H:
OUTSEL[7..0]
D7 to D4:
0: FrameTriggerWait signal,
1: UserOutput signal,
2: ExposureActive signal,
3: TriggerAuxiliary signal,
5: SensorReadOut signal,
6: StrobeSignal signal,
7 to F: No function
D3 to D0:
0: FrameTriggerWait signal,
1: UserOutput signal,
2: ExposureActive signal,
3: TriggerAuxiliary signal,
5: SensorReadOut signal,
6: StrobeSignal signal,
7 to F: No function
Command descriptions
[The output signal selection for the power/IO connector] Initial data: OUTSEL[7..0] = 20H
Sets the output signal from the power/IO connector.
Sets the active time for the strobe signal as usecond.
Active time for the strobe signal = (STROBEON_I[23..0]). (STROBEON_F[7..0]) useconds
[The strobe signal active time (usecond, integer)]
Initial data: STROBEDELAY_I[23..0]
=
0, data range: 0 to 2,000,000
Sets the active time for the strobe signal as usecond.
Active time for the strobe signal = (STROBEON_I[23..0]). (STROBEON_F[7..0]) useconds
(Prohibited setting. Do not set this value)
Output signal for 3 pin of the power/IO connector
"UserOutput signal for the power/IO connector(TEST2-D3,4)".
Note: When select "UserOutput signal", sets the status of the signal with
4: TriggerInternal signal (after mask and delay process),
(Prohibited setting. Do not set this value)
D[7..0]
Output signal for 4 pin of the power/IO connector
4: TriggerInternal signal (after mask and delay process),
Active time for the strobe signal specifies as below:
[The strobe signal active time (usecond, decimal)]
D7 D6 D5 D4 D3 D2 D1 D0