No.11S098-03
68
STC-GE33OX/GEC33OX
Users guide Rev. 1.03
Command No.
92H:[7..0]
D7 to D2: No function
Sets always as "000000"
D1 to D0:
00: Hold,
01: Open,
10: Close,
11: No fucntion
(Prohibited setting. Do not set this value)
C0H:[7..0]
D7 to D6: No function
Sets alwayas as "00"
D5 to D4:
11: Color interpolation
D3 to D2: No function
Sets alwayas as "00"
D1 to D0:
(Prohibited setting. Do not set this value)
Command descriptions
Manual adjustment operation
[Iris lens manual adjustment] Initial data: 01H
Sets the iris lens manual adjustment operation.
D[7..0]
[Image data between FPGAs] Initial data: 00H
D[7..0]
Image process after the image data from the user configurable FPGA
00: No process (No data from use FPGA),
(No image data from the use configurable FPGA)
01: White balance, gamma and color interpolation,
10: Gamma and color interpolation,
11: No function
Note: White balance and color interpolation process are available only for color camera.
Image data from Sentech FPGA to the user configurable FPGA
00: CCD out image data,
01: White balance processed image data,
10: White balance and gamma processed image data,
D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0