No.11S098-03
20
STC-GE33OX/GEC33OX
Users guide Rev. 1.03
3.2.2.2 Configuration data
1) The FPGA program created by users is sent to "Configuration ROM" through the Ethernet connector as
"Configuration data".
2) The data is sent through "GigE I/F" and "Sentech FPGA" to "Configuration ROM" and stored.
(Note) Please see
“
User configurable FPGA (XILINX) uploading instructions
” for more detailed
information.
3) Select
“Enable” at “User FPGA Enable” when the user configurable FPGA has to configure with the
uploaded configure data for the user configurable FPGA.
The user configurable FPGA does not work if select
“Disable” at “User FPGA Enable”.
A)
By using Sentech GUI “StCamGigEWare_OpDemo”
Also please see
User configurable FPGA (XILINX) Sample Codes
.
a) Select
“OP Setting” under “Option” in the menu.
b) Select which image data sends from
“Sentech FPGA” to “User configurable FPGA” at
“Sentech FPGA -> User FPGA”
B) By changing the register value through the UART
Also please see section
“6 The communication protocol specifications”.
a) Set
01H for the “Use FPGA Enable” (Device code: 20H, command: 19H).