The Menu
40
3.
Polarity
The output polarity defines how the actor is activated. If the actor should be switched
on by a voltage on the port, it is „active high“. This is the case for a normally closed
solenoid valve for the water refilling. “Active low” would mean that if the output is
activated, the voltage is reduced from 24 V to 0 V so that the actor can be activated (for
example a normally opened solenoid valve).
Switch on for
To switch the output port on manually, you can select here the duration. Confirm with OK.
Plug name
With plug name you can give the output a name of max. 8 characters, which will be displayed
in the SENECT Control App.
Hour meter
To see how long an output was activated, you can use the “hour meter” menu item. Here you can set
it to zero and from then on, there will be displayed in the screen of the corresponding output in the
bottom line the hours of activation (press in the home screen
to switch to the output screens and
then
until you are the selected output port).
This function can be for instance be used to estimate exchange intervals of actuators, e.g. UVC
lamps.
Menu WLAN
Additional information and help with respect to the wifi connectivity can
be found on the SENECT forum under:
Info
Info
shows
information
about
the
current
WLAN
connection
of
your
AQUACULTURE|CONTROL.
SSID: WLAN network name
Signal: Signal strength of the connection (should be between -20 dB (strong) and -70 dB
(weaker))
Fig. 11: QR Code with a link
to the SENECT forum.