The Menu
29
Intensive cleaning
Since the filter mesh can clog regularly by biofouling or calcareous crusts, the
FITLER|CONTROL initiates in regular intervals an intensive cleaning mode where by a
reduction of the motor speed the filter mesh is cleaned more intensively.
Interval
The interval defines, how often the intensive cleaning programme should be run.
Duration
With the duration, you can choose how long the intensive cleaning programme should
activate the filter. The drum should be rotated at least one time full.
Motor speed
To intensify the cleaning, the motor speed is reduced. Here you can choose the speed from
20% (slow) to 100% (max. speed).
Motor speed
This menu item is the same as mentioned above, but valid for the normal flushing.
Eco-Mode
With the Eco-Mode you can decrease the water consumption of your filter. When the water
level sensor initiates the cleaning, only the filter motor is activated for a short time to bring
the until then unused filter mesh into the water. By monitoring the water level, the
AQUACULTURE|CONTROL will decide when the next full cleaning is necessary.
In this menu item, you can set how long every partial rotation of the drum should last.
Alarm
The alarm mode specifies, when you will be alarmed. Several events can cause alarms:
Dry run protection (can´t be switched off)
Forced Clean. Cycle (when the filter is backwashed, but the water level still
decreases and the filter is forced to be cleaned again)
Service interval (here you can select to be alarmed regularly e.g. when the filter
has been backwashed 10.000 times. This function is intended to be a reminder for
any maintenance work)
High clean int.: If the filter has an increased flushing frequency, you can receive an
alarm message. Set therefore the time of 10 cleaning cycles. If the filter flushes
more than 10 times in the specified time, you will receive an alarm message.