The Menu
33
Plug 1 to 6 / 230 V Plug 1 to 3
Please note that 230 V plugs can only be switched on and off while the actuator output ports
can also control the output strength (e.g. only 75% of the output signal strength).
Functions
Select here the function of the plug. You can choose between:
1.
Deactivate
2.
Filter Motor
3.
Filter Pump
4.
Circulation Pump
5.
Sensor Control
6.
Feeder
7.
Time Control
8.
Constant on
9.
UVC Lamp
10.
Alarm
Description of the major output functions
Filter Motor
If the function „Filter motor“ is selected, the ouput is active when the filter motor is activated.
By using output signals like 4-20 mA, you can for example also control variable frequency
drives for using 380 V motors.
To control the motor speed via 4-20 mA and switching it on and off with 24 V DC, please select
as “Additional function “ “Var. Frequency Drive” (see also page 13).
Spray pump
Defined as „Spray pump“, the output is activated, as defined in the filter settings.
Circulation pump
When defined as „circulation pump“, the output is switched on in normal mode, but will be
switched off in case of alarming (e.g. water level below dry-run protection). Additionally, the
circulation pump can be switched on and off with the STOP button (break symbol in the
display). Additional functions can be added.
Содержание AQUACULTURE AQC-A1-333-150