Backwash Parameter
Here you can set all relevant parameters for the filter cleaning.
Backwash Duration
The backwash duration defines the time of one cleaning cycle. Choose the flush time so
that the drum is rotated at least one time completely.
Pre-flushing time
With the pre-flushing time, you can define how long the spray pump is activated before the
filter motor starts.
Post-flushing time
To discharge also the last rest of particles from the flush tray, you can set with the post-
flushing time the duration, how long the spray pump should stay activated after the filter
motor stops.
Cleaning pause
The cleaning pause defines the minimal temporal distance between two filter cleaning
events. This break prevents from water loss associated from too man cleaning events. But
in case the water level drops further towards the emergency level, the filter flushes despite
there is a cleaning pause. This function disables the cleaning pause in situations, when
urgent cleaning is necessary.
Forced Clean. Cycle
Here, you can specify how often the filter should be backwashed even when the sensor
does not detect the necessity of backwashing. This means that you can set here the
maximum time where the filer is not flushed.