Getting started
13
3.) Filter motor
24 V DC Filter motors:
Ensure that the filter motor is correctly installed at your filter and check in the technical
documentation, if the motor can be operated with 24 V DC (max. current 5 or 10 A). If yes,
you can connect the motor with the optional available motor cable (Art. No.: 3400, polarity:
red = +, black = -). Connect the motor cable plug to the high-power actuator output port
OUT 3.
230 V AC Filter motors:
If your filter is equipped with a 230 V AC motor, connect its plug with the main plug 2 (230 V
OUT 2). Please consider that only motors with a power of max. 500 W can be connected
directly here. Motors with a higher power consumption can be connected to the other two
230 V PLUG 1 or 230 V PLUG 3, in case these are not needed for other consumers like a spray
pump or can be connected to actuator output ports via the optional Power Switch 24-230 (Art.
No.: 3100).
Note here, that all functions where the motor speed is controlled by the
AQUACULTURE|CONTROL do not work, because there is just an on / off switching of the filter
motor possible. These functions are:
Intensive cleaning programme
Soft motor start
High-pressure cleaning mode
If you want to use these functions with AC motors, you need a variable frequency drive to
control the motor speed.
230 V / 400 V AC Filter motors connected via variable frequency drive (VFD):
For changing the rotation speed of AC filter motors, which allows to use all functions which
change the motor speed, a variable frequency drive between the AQUACULTURE |CONTROL
and the filter motor is necessary.
SENECT offers fully parametrized and wired VFDs. The green labelled actuator cable from the
VFD must be connected to one the actuator output ports, e.g. OUT 1.