EN
59
8. Technical data
Series
Torque
Nm
Speed
rpm
Power input
A
Output
W
2/7
7
17
0.41
95
2/10
10
17
0.55
124
2/15
15
17
0.66
152
2/20
20
17
0.75
172
2/30
30
17
0.95
220
2/40
40
17
1.5
345
2/50
50
12
1.5
345
Installation location:
After installing the drive, mark the drive type in the technical data table and make a note of
the installation location.
Series 2 drives have a plug-in connection cable. Series 1 and series 3 drives have a 2.5 m
mains cable as standard which is permanently installed and cannot be changed!
The respective cable lengths and cable qualities for series 1, series 2 and series 3 drives can
be selected from the catalogue.
Connection cables must be ordered separately.
Ask for information about connecting special plug connectors.
Information for all drive types:
Nominal voltage: 230 V AC/50 Hz
Standby consumption: 0.5 W
Protection class: IP 44
Operating time: 4 min.
Radio frequency: 868.1 MHz
Transmission power: max. 10 mW
Note: The maximum radio range is up to 25 m indoors and up to 350 m outdoors.
Subject to technical modifications.
9. General declaration of conformity
SELVE GmbH & Co. KG hereby declares that the SE Breeze-com drive complies with the
fundamental requirements and other relevant specifications of Directives 2006/42/EC,
2014/53/EU, 2014/30/EU and 2011/65/EU. The declaration of conformity can be viewed on
www.selve.de
Technical data/General declaration of conformity