24
ACTIVATION
To Activate the XP 5, press and release the Front (Advance) button.
Backup Activation (only functional if the Water Activation feature is set ON)
As a backup, the XP 5 will also automatically activate by water contact. This is
accomplished by bridging the gap between contacts located on the stems of the
control buttons and back of the module. The H2O graphic that will be displayed as an
indication is described later. If the Water Activation feature (a user setting) is set OFF,
the XP 5 will only activate by push button and only if shallower than 4ft (1.2m) depth.
• Upon manual activation, the unit will enter Diagnostic Mode
(Fig. 15), displaying all segments of the LCD (as 8's), fol-
lowed by dashes, then a countdown from 9 to 0.
• Diagnostic Mode checks the display and battery voltage to
ensure that everything is within tolerance and functioning
properly. The Battery icon will not be displayed during
Diagnostic Mode.
• It will also check the ambient barometric pressure, and cali-
brate its present depth as zero. At elevations of 2,000 feet
(610 meters) or higher, it will recalibrate itself to measure
depth in feet of fresh water instead of feet of sea water.
• If values are acceptable, the unit will enter Surface Mode. If
any value is not acceptable, the unit will shut down in 5 sec.
• If no dive is made within 2 hours after initial activation, the
unit will automatically deactivate. If the wet contacts are still
bridged, the unit will then reactivate and display the `H2O`.
Fig. 15 - Diagnostic Mode
Содержание XP5
Страница 1: ...SEEMANN XP 5 OWNER S GUIDE ...
Страница 7: ...7 FEATURES and DISPLAYS ...
Страница 45: ...45 PRE DIVE PLAN MODE ...
Страница 65: ...65 POST DIVE MODES ...
Страница 75: ...75 SIMULATOR DEMO MODE ...
Страница 83: ...83 CARE MAINTENANCE and SERVICE ...
Страница 91: ...91 REFERENCE ...
Страница 106: ...106 NOTES ...