16
Low Battery Condition
Voltage level is checked upon activation and every 10 min-
utes during operation.
• If a Low Battery Condition exists when the unit is acti-
vated (by pressing the button), the Battery icon will ap-
pear flashing once per second for 5 seconds (Fig. 8) fol-
lowed by shutdown of the unit.
• If the button is not pressed to activate the unit prior to a
dive, and a Low Battery Condition exists, the Low
Battery icon will appear flashing as a warning upon
descent past 4 feet (1.2 meters). No other information
will be displayed.
• If the unit did not display the Low Battery icon 'prior to'
entering the Dive Mode, and a Low Battery Condition oc-
curs during the dive, there will be sufficient battery
power to maintain unit operation for the remainder of 'that
dive'. The Low Battery icon will appear upon surfacing
when Surface Mode is displayed.
When the Battery is removed, nitrogen and oxygen
calculations for repetitive dives are reset to zero after 10
seconds. Also, settings such as Time, Date, and FO2 must
be reset. If a new battery can be inserted within 10
seconds, the calculations and settings will be retained.
NOTE: Battery change procedures are
described on page 84 of this manual.