20
User Menu
ARM/DIS (arm & disarm)
NO
SYS STAT (system status)
NO
ALM SLNC (alarm silence) NO
SYS TEST (system test)
NO
SNSR RST (sensor reset)
NO
USR CODE (user codes)
NO
DOOR ACS (door access)
NO
SCHEDULS (schedules)
NO
ARM AREA (armed areas) NO
TIME (time)
NO
OUTPUTS (outputs on off)
NO
DIS EVNT (display events)
NO
LP STATS (loop status)
NO
EXTEND (extend closing)
NO
BYPASS LP (bypass loops) NO
*
TEMP CODE (temporary code) NO
LOOP MON (loop monitor) NO
* The display TEMP CODE NO YES is defaulted to NO.
• NO makes this a permanent user code.
• YES makes this a temporary code that expires in 7 days.
10. Press the ARROW key once to add another user or twice to exit
from the User Menu.
Ambush Codes
Your system may be programmed to allow user number 1 to be an
Ambush code. This Ambush code functions identically to a standard
code with the exception that it sends a silent alarm to the central
station. This silent alarm alerts the operator to a duress situation at
the premises and prompts the immediate notification of the proper
authorities.
Refer to the System Setup section of this guide to see if your system
is programmed for Ambush. If so, do NOT program a code for user
number 1 unless you intend to use the Ambush function.
User Codes
continued
Adding User Code Numbers:
1. Access the User Menu.
2. Press the COMMAND key until USER CODES? displays.
3. Press any one of the SELECT keys. The keypad displays ADD
DEL CHG.
4. Press the SELECT key under ADD to add a new user code. You
must have a user code level of 9 or have a custom user code with
that authority to be able to add a user code.
5. At the USER NUMBER: - prompt, enter a user number and
press COMMAND. The displays changes to CODE NO: .
Refer to the System Setup section of this guide for the number of user
codes available for your system.
6. Enter a user code number of 1 to 5 digits and press COMMAND.
This is the number they will use each time they arm, disarm, or
make changes to the system.
7. At the AREAS: display, enter the area numbers where this user
will have access. For example, press the 1 key for area 1.
8. The display changes to LEVEL CUSTOM. Select LEVEL to
assign a standard set of authorized functions as outlined in the
User Code Levels table.
9. At the LEVEL: - display, enter an authority level from 1 to 9.
Press COMMAND. The displays shows USER # ADDED.
10. Select CUSTOM to customize the functions you want the user to
access. This allows users to have certain capabilities outside of
a standard authority level. The following chart shows the custom
menu with default selections.