![Sea-Bird Scientific Deep SeapHOx V2 Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/sea-bird-scientific/deep-seaphox-v2/deep-seaphox-v2_user-manual_1221397049.webp)
9.2.3 Message tab
The software automatically saves files that have information about sensor use, data
collection, and software operation over time. This information helps the user and
Customer Support find problems and do troubleshooting.
When the "Display Dialog for Error Level Messages" box has a check in it, the software
saves one of five levels of error messages.
•
INFO
—The default level. All high-level operations are saved.
•
ERROR
—Minimum level. Only errors that need to be examined by the user or
Customer Support are saved.
•
WARN
—Low level. The files that are saved do not have enough information for the
user to make an analysis of how the sensor is used and set up.
•
DEBUG
—High level. Used for troubleshooting.
DEBUG
and
TRACE
files are very
large.
•
TRACE
—The highest level. Used only for troubleshooting.
"Daily Files"—all messages from a single day are saved in one file.
"Rolling Files"—all messages are saved in one file until it is the maximum size specified
by the user. The messages are then saved to a new file. The user specifies the number of
files to keep. The oldest files are erased first.
"Save Lost Bytes"—if this box has a check in it, the software saves all of the unexpected
output from the sensor to a file.
"File Location"—the operating system of the PC determines where these files are saved.
9.3 Sensor menu
The
Sensor
menus have options for each sensor with which the software communicates.
Refer to the sections on
on page 45 for more information about these
items.
Advanced Sensor menu items
Common
•
Set Clock
lets the user synchronize the time between the PC and the sensor.
•
Summary Report
lets the user get a summary of the settings stored in the sensor.
•
Collect Diagnostics
is helpful for troubleshooting.
9.3.1 SeaFET, SeapHOx
•
Erase Saved Data
lets the user erase all of the data saved in the sensor.
•
Edit Data File Headers
lets the user put labels on data files.
•
Upgrade Firmware
lets the user install the latest firmware from the manufacturer.
9.4 Data menu
The
Data
menu has sensor-specific options to look at data that has been saved to a PC.
Software reference
47
Содержание Deep SeapHOx V2
Страница 2: ......
Страница 8: ...2 1 3 Illustrations Figure 1 SeaFET V2 dimensions Specifications 6 ...
Страница 9: ...Figure 2 Y cable for SeapHOx V2 Figure 3 Data I O cable Specifications 7 ...
Страница 12: ...Specifications 10 ...
Страница 16: ...Product overview 14 ...
Страница 26: ...Deployment and recovery 24 ...
Страница 42: ...Maintenance 40 ...
Страница 46: ...Reference 44 ...
Страница 50: ...Software reference 48 ...
Страница 55: ......