Assembly
07.00 | GSM-P | Assembly and Operating Manual | en | 389104
23
Mounting of the
sensor
Ø
To relieve the cable, the electronics have to be fixed in place us-
ing cable ties (7). There are ribs (6) in place on the electronics
for mounting purposes.
Ø
Orient the sensor towards the mark on the housing (1) of the
pneumatic module
OR
Ø
Insert it up to the clamping stop (many SCHUNK products are
prepared for this)
Ø
Fix the sensor with the Allen key.
Should there be no mark on the housing, insert the magnetic switch according to dimension l2 or according to dimension l1 and then fix it with an Allen key.
Installation dimensions for MMS-P
GSM Type
Dimension l1
Dimension l2
Dimension l3
GSM-P-32
8.9
0
-
GSM-P-32-AS
8.9
0
-
GSM-P-32-IS
20.05
11.15
6.15
GSM-P-40
13.9
5
0
GSM-P-40-AS
13.9
5
0
GSM-P-40-IS
31.5
22.6
17.6
GSM-P-50
16.9
8
3
GSM-P-50-AS
16.9
8
3
GSM-P-50-IS
36.7
27.8
23
GSM-P-64
13.9
5
0
GSM-P-64-AS
13.9
5
0
GSM-P-64-IS
26.25
16.35
11.35