Assembly
07.00 | GSM-P | Assembly and Operating Manual | en | 389104
21
4.3.3 Assembly and setup of the MMS-P 22
Position and installation of the MMS-P magnetic switches
1
Sensor MMS-P
(left groove)
Monitoring gripper position 1 and gripper
position 2 in the left rotating angle end po-
sition (signals SGL1 and SGL2)
2
Sensor MMS-P
(right groove)
Monitoring gripper position 1 and gripper
position 2 in the right rotating angle end
position (signals SGR1 and SGR2)
3
Stop for MMS-P Determining the clamping position of the
MMS-P sensor
Monitoring GSM locations/positions/end positions:
SGL1: left rotating angle end position, gripper position 1
SGL2: left rotating angle end position, gripper position 2
SGR1: right rotating angle end position, gripper position 1
SGR2: right rotating angle end position, gripper position 2
The monitoring of swiveling and grasping movements with an
magnetic switch can yield reliable results only in the ranges of 0°
±3° and 180°±3° or 0°±3° and 90°±3°.