Assembly
20
07.00 | GSM-P | Assembly and Operating Manual | en | 389104
4.3 Mounting the sensor
NOTE
Observe the assembly and operating manual of the sensor for
mounting and connecting.
The product is prepared for the use of sensors.
• For the exact type designations of suitable sensors, please see
catalog datasheet and Link Übersicht Sensoren.
• For technical data for the suitable sensors, see assembly and
operating manual and catalog datasheet.
– The assembly and operating manual and catalog datasheet
are included in the scope of delivery for the sensors and are
available at schunk.com.
• Information on handling sensors is available at schunk.com or
from SCHUNK contact persons.
4.3.1 Overview of sensors
Designation
GSM-P
22
32
42
52
Magnetic switch MMS 30
X
X
X
X
Inductive proximity switch IN 80
X
X
X
X
Flexible position sensor FPS-S 13
X
X
X
4.3.2 Switch-off hysteresis
Sensors MMS 22, MMS-P 22, MMS 22-PI1 and MMS 22-PI2
The smallest detectable difference in stroke is defined in the fol-
lowing table:
The smallest detectable difference in stroke based on the nominal stroke
For grippers with X mm
nominal stroke per jaw
Min. query range per jaw/
min. queried stroke difference per jaw
X ≤ 5 mm
30% of the nominal stroke per jaw
X > 5 mm to X ≤ 10 mm
20% of the nominal stroke per jaw
X > 10 mm
10% of the nominal stroke per jaw
Example:
Product with 7 mm nominal stroke per jaw
7 mm * 20 % = 1.4 mm