Assembly
07.00 | GSM-P | Assembly and Operating Manual | en | 389104
19
"A" - "D" are main connections, "a" - "d" are direct connections
Connection
Function
Hose connection A
Swivel toward 180° or 90°
position
Hose-free direct connection a
Hose connection B
Swivel toward 0° position
Hose-free direct connection b
Hose connection C
Move gripper into »OPEN«
position
Hose-free direct connection c
Hose connection D
Move gripper into »CLOSED«
position
Hose-free direct connection d
Connections “C” and “D” for the modules with a base cross section
of 25x25 are slightly offset from center
If direct connections "a" – "d" are used, use the locking screws in-
cluded in the accessory pack for the corresponding main connec-
tions "A" – "D".
If air connections "a" – "d" are used, ensure sufficient throttling,
which can be set by means of exhaust air throttling. To do this, the
throttle reductions for the main connections, which are designed
for a medium load, can be attached to the adapter plate, for ex-
ample.
• Open only the air connections that are needed.
• Close unused main air connections using the screw plugs from
the enclosed pack.
• For a hose-free direction connection, use the O-rings from the
enclosed pack.